{"items":[{"id":431,"text":"Solidvar DC","nick":"Contactores de Estado Sólido – Corriente Continua","emphasis":1,"files":[{"id":26761,"name":"solidvar site 1","ext":"png","link":"2025/6/20250625114939799","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":109,"text":"Modelos","type":1,"pre":"","pos":""},"values":[{"id":564,"text":"De 20 a 800A DC"}]},{"property":{"id":110,"text":"Tensiones Nominales","type":1,"pre":"","pos":""},"values":[{"id":565,"text":"48 a 600 VDC"}]},{"property":{"id":111,"text":"Tensiones de Control","type":1,"pre":"","pos":""},"values":[{"id":566,"text":"20 a 50 VAC/VDC"},{"id":567,"text":"100 a 240 VAC/VDC"}]},{"property":{"id":112,"text":"Contactos Auxiliares Estáticos","type":1,"pre":"","pos":""},"values":[{"id":568,"text":"2 NA + 2 NC (10 a 250 VAC/VDC – 1A máx)"}]}],"category":{"id":34,"text":"Accionamiento de Banco de Condensadores"}},{"id":329,"text":"Solidvar","nick":"Contactores de Estado Sólido","emphasis":1,"files":[{"id":20564,"name":"solidvar site 1","ext":"png","link":"2024/8/20240812132321793","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":1,"text":"Tensión","type":1,"pre":"","pos":""},"values":[{"id":76,"text":"Nominal: 220 a 550V"}]},{"property":{"id":9,"text":"Alimentación Eléctrica","type":1,"pre":"","pos":""},"values":[{"id":78,"text":"20 a 50 VAC/VDC"},{"id":79,"text":"100 a 240 VAC/VDC"},{"id":80,"text":"110 VAC y 220 VAC"}]},{"property":{"id":44,"text":"Versión","type":1,"pre":"","pos":""},"values":[{"id":174,"text":"Monofásico"},{"id":175,"text":"Bifásico"},{"id":176,"text":"Trifásico"}]},{"property":{"id":54,"text":"Grado de Protección","type":1,"pre":"","pos":""},"values":[{"id":472,"text":"IP20"}]},{"property":{"id":63,"text":"Corrientes Nominales","type":1,"pre":"","pos":""},"values":[{"id":441,"text":"20 a 2000A"}]},{"property":{"id":66,"text":"Velocidad de Funcionamiento","type":1,"pre":"","pos":""},"values":[{"id":446,"text":"20.000 maniobras por hora (máximo)."}]},{"property":{"id":67,"text":"Duración","type":1,"pre":"","pos":""},"values":[{"id":447,"text":"Más de 20 años o 200 millones de maniobras."}]},{"property":{"id":68,"text":"Temperatura Ambiente","type":1,"pre":"","pos":""},"values":[{"id":448,"text":"0 a 40°C (hasta 75°C con derating)."}]},{"property":{"id":69,"text":"Aislamiento entre Control y Potencia","type":1,"pre":"","pos":""},"values":[{"id":449,"text":"2.500V"}]},{"property":{"id":70,"text":"Aislamiento entre Potencia/Masa","type":1,"pre":"","pos":""},"values":[{"id":450,"text":"1.500V"}]},{"property":{"id":82,"text":"Tensión Máxima de Trabajo","type":1,"pre":"","pos":""},"values":[{"id":496,"text":"600 VAC"}]}],"category":{"id":34,"text":"Accionamiento de Banco de Condensadores"}},{"id":330,"text":"Relés de Estado Sólido","nick":"Accionamento de Cargas Resistivas","emphasis":1,"files":[{"id":20615,"name":"site 1","ext":"png","link":"2024/8/20240814093903467","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":1,"text":"Tensión","type":1,"pre":"","pos":""},"values":[{"id":85,"text":"rigidez dieléctrica: 2500V"}]},{"property":{"id":21,"text":"Frecuencia","type":1,"pre":"","pos":""},"values":[{"id":81,"text":"47 ~ 63Hz"}]},{"property":{"id":22,"text":"Carga","type":1,"pre":"","pos":""},"values":[{"id":82,"text":"Resistiva"}]},{"property":{"id":23,"text":"Accionamiento","type":1,"pre":"","pos":""},"values":[{"id":87,"text":"Zero voltage"}]},{"property":{"id":24,"text":"Tiempo de Respuesta","type":1,"pre":"","pos":"ciclo rede"},"values":[{"id":83,"text":"0.5"}]},{"property":{"id":25,"text":"Temperatura de Funcionamiento","type":1,"pre":"","pos":""},"values":[{"id":84,"text":"-30°C ~ +80° C"}]},{"property":{"id":26,"text":"Corriente de Fuga","type":3,"pre":"<= ","pos":"mA"},"values":[{"id":88,"text":""}]}],"category":{"id":25,"text":"Accionamiento de Cargas Resistivas"}},{"id":345,"text":"Poweramp","nick":"Sistemas de Control y Excitación para Motores de Media Tensión","emphasis":11,"files":[{"id":20562,"name":"poweramp site 1","ext":"png","link":"2024/8/20240812132041810","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":18,"text":"Corriente","type":1,"pre":"","pos":""},"values":[{"id":91,"text":"1A a 800A"}]},{"property":{"id":27,"text":"Slip Ring","type":1,"pre":"","pos":""},"values":[{"id":92,"text":"Brushless de hasta 13.8 KV"}]}],"category":{"id":127,"text":"Sistemas de Excitación para Motores Síncronos"}},{"id":10,"text":"Mykron","nick":"Controlador de Potencia","emphasis":1,"files":[{"id":20559,"name":"mykron site 1","ext":"png","link":"2024/8/20240812130429041","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":9,"text":"Alimentación Eléctrica","type":1,"pre":"","pos":""},"values":[{"id":80,"text":"110 VAC y 220 VAC"}]},{"property":{"id":18,"text":"Corriente","type":1,"pre":"","pos":""},"values":[{"id":97,"text":"10A a 2000A"}]},{"property":{"id":44,"text":"Versión","type":1,"pre":"","pos":""},"values":[{"id":174,"text":"Monofásico"},{"id":175,"text":"Bifásico"},{"id":176,"text":"Trifásico"}]},{"property":{"id":45,"text":"Módulo de Control","type":1,"pre":"","pos":""},"values":[{"id":177,"text":"Único para todas las bandas"}]},{"property":{"id":46,"text":"Limitación de Corriente","type":1,"pre":"","pos":""},"values":[{"id":178,"text":"Ajustable"}]},{"property":{"id":61,"text":"Funciones / Modos de Operación","type":1,"pre":"","pos":""},"values":[{"id":435,"text":"Normal / Corriente constante"},{"id":436,"text":"Limitador de corriente ajustable"},{"id":437,"text":"Integrador de corriente"}]},{"property":{"id":62,"text":"Tensión Nominal","type":1,"pre":"","pos":""},"values":[{"id":438,"text":"220V"},{"id":439,"text":"380V"},{"id":440,"text":"440V"}]}],"category":{"id":25,"text":"Accionamiento de Cargas Resistivas"}},{"id":432,"text":"Mag V DC","nick":"Convertidores para Electroimanes DC","emphasis":1,"files":[{"id":26770,"name":"site 2","ext":"png","link":"2025/6/20250625144017549","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":30,"text":"Desmagnetización","type":1,"pre":"","pos":""},"values":[{"id":575,"text":"Ajustable – 0,4 a 10 segundos"}]},{"property":{"id":45,"text":"Módulo de Control","type":1,"pre":"","pos":""},"values":[{"id":576,"text":"Plug-in con indicación de fallas"}]},{"property":{"id":63,"text":"Corrientes Nominales","type":1,"pre":"","pos":""},"values":[{"id":569,"text":"50 a 300 A CC"}]},{"property":{"id":65,"text":"Tensiones de mando","type":1,"pre":"","pos":""},"values":[{"id":570,"text":"24 VCC"}]},{"property":{"id":67,"text":"Duración","type":1,"pre":"","pos":""},"values":[{"id":574,"text":"Más de 20 millones de maniobras"}]},{"property":{"id":75,"text":"Módulo de Disparo","type":1,"pre":"","pos":""},"values":[{"id":577,"text":"Aislados y con detección de fallas"}]},{"property":{"id":113,"text":"Tensión del Ventilador","type":1,"pre":"","pos":""},"values":[{"id":571,"text":"24 VCC"},{"id":572,"text":"127 VCA"},{"id":573,"text":"220 VCA"}]},{"property":{"id":114,"text":"Contactos Auxiliares de Salida","type":1,"pre":"","pos":""},"values":[{"id":578,"text":"1 NA (Mag) y 1 NC (Desmag)"}]},{"property":{"id":115,"text":"Aislamiento Mando / Potencia","type":1,"pre":"","pos":""},"values":[{"id":579,"text":"3500 V"}]}],"category":{"id":51,"text":"Convertidores AC/DC"}},{"id":351,"text":"Mag V","nick":"Convertidores para Electroimanes (VRT)","emphasis":1,"files":[{"id":20557,"name":"magv site 1","ext":"png","link":"2024/8/20240812113746050","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":17,"text":"Humedad Relativa","type":1,"pre":"","pos":""},"values":[{"id":470,"text":"0 a 90% sin condesación"}]},{"property":{"id":18,"text":"Corriente","type":1,"pre":"","pos":""},"values":[{"id":464,"text":"20A a 50A"}]},{"property":{"id":28,"text":"Suministro","type":1,"pre":"","pos":""},"values":[{"id":100,"text":"Solución Completa"}]},{"property":{"id":45,"text":"Módulo de Control","type":1,"pre":"","pos":""},"values":[{"id":469,"text":"Encapsulado en resina epoxi con aislamiento de 20.000 V/mm."}]},{"property":{"id":54,"text":"Grado de Protección","type":1,"pre":"","pos":""},"values":[{"id":472,"text":"IP20"}]},{"property":{"id":65,"text":"Tensiones de mando","type":1,"pre":"","pos":""},"values":[{"id":465,"text":"100 a 230VAC"},{"id":466,"text":"25 a 110 VAC"}]},{"property":{"id":67,"text":"Duración","type":1,"pre":"","pos":""},"values":[{"id":447,"text":"Más de 20 años o 200 millones de maniobras."}]},{"property":{"id":68,"text":"Temperatura Ambiente","type":1,"pre":"","pos":""},"values":[{"id":468,"text":"0 a 50°C."}]},{"property":{"id":74,"text":"Hora de llamada","type":1,"pre":"","pos":""},"values":[{"id":467,"text":"0,5 a 5 seg."}]},{"property":{"id":76,"text":"Altitud","type":1,"pre":"","pos":""},"values":[{"id":471,"text":"Hasta 1000 metros."}]},{"property":{"id":77,"text":"Tensión de Red Máxima","type":1,"pre":"","pos":""},"values":[{"id":473,"text":"230VAC"}]}],"category":{"id":51,"text":"Convertidores AC/DC"}},{"id":9,"text":"Hyamp","nick":"Sistemas Completos de Control de Potencia","emphasis":1,"files":[{"id":20556,"name":"hyamp site","ext":"png","link":"2024/8/20240812113428837","lang":"PT","role":"certificate"}],"properties":[],"category":{"id":121,"text":"Accionamiento de Cargas"}},{"id":354,"text":"Evomag","nick":"Sistemas Completos de Electroimanes con No-Break","emphasis":1,"files":[{"id":20547,"name":"Evomag2","ext":"png","link":"2024/8/20240809152518091","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":1,"text":"Tensión","type":1,"pre":"","pos":""},"values":[{"id":109,"text":"Personalizable"}]},{"property":{"id":18,"text":"Corriente","type":1,"pre":"","pos":""},"values":[{"id":101,"text":"Customizable"}]},{"property":{"id":29,"text":"Conmutación","type":1,"pre":"","pos":""},"values":[{"id":106,"text":"DC con estático"},{"id":112,"text":"DC con contactores"}]},{"property":{"id":30,"text":"Desmagnetización","type":1,"pre":"","pos":""},"values":[{"id":107,"text":"Automático con activo"},{"id":113,"text":"Automático con resistencias"}]}],"category":{"id":123,"text":"Accionamiento de electroimanes"}},{"id":7,"text":"CM-VRT","nick":"Sistema Completo de Conversión AC/DC para Electroimanes","emphasis":1,"files":[{"id":20234,"name":"CM-VRT(3)","ext":"png","link":"2024/7/20240730091629790","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":30,"text":"Desmagnetización","type":1,"pre":"","pos":""},"values":[{"id":114,"text":"0,4 a 10 segundos"}]},{"property":{"id":63,"text":"Corrientes Nominales","type":1,"pre":"","pos":""},"values":[{"id":569,"text":"50 a 300 A CC"}]},{"property":{"id":65,"text":"Tensiones de mando","type":1,"pre":"","pos":""},"values":[{"id":445,"text":"110VAC y 220VAC"}]},{"property":{"id":67,"text":"Duración","type":1,"pre":"","pos":""},"values":[{"id":447,"text":"Más de 20 años o 200 millones de maniobras."}]},{"property":{"id":71,"text":"Tensión de Salida","type":1,"pre":"","pos":""},"values":[{"id":584,"text":"35% mayor que la tensión de entrada"}]},{"property":{"id":113,"text":"Tensión del Ventilador","type":1,"pre":"","pos":""},"values":[{"id":583,"text":"110 o 220 VCA"}]},{"property":{"id":116,"text":"Tensión Máxima de Entrada","type":1,"pre":"","pos":""},"values":[{"id":585,"text":"300 VCA"}]}],"category":{"id":123,"text":"Accionamiento de electroimanes"}}]}