{"items":[{"id":432,"text":"Mag V DC","nick":"Converters for Electromagnets DC","emphasis":1,"files":[{"id":26770,"name":"site 2","ext":"png","link":"2025/6/20250625144017549","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":30,"text":"Demagnetization","type":1,"pre":"","pos":""},"values":[{"id":575,"text":"Adjustable – 0.4 to 10 seconds"}]},{"property":{"id":45,"text":"Control Module","type":1,"pre":"","pos":""},"values":[{"id":576,"text":"Plug-in with fault indication"}]},{"property":{"id":63,"text":"Nominal Currents","type":1,"pre":"","pos":""},"values":[{"id":569,"text":"50 to 300 A CC"}]},{"property":{"id":65,"text":"Command Voltages","type":1,"pre":"","pos":""},"values":[{"id":570,"text":"24 VCC"}]},{"property":{"id":67,"text":"Lifetime","type":1,"pre":"","pos":""},"values":[{"id":574,"text":"More than 20 million operations"}]},{"property":{"id":75,"text":"Trigger Module","type":1,"pre":"","pos":""},"values":[{"id":577,"text":"Isolated and with fault detection"}]},{"property":{"id":113,"text":"Fan Voltage","type":1,"pre":"","pos":""},"values":[{"id":571,"text":"24 VCC"},{"id":572,"text":"127 VCA"},{"id":573,"text":"220 VCA"}]},{"property":{"id":114,"text":"Output Auxiliary Contacts","type":1,"pre":"","pos":""},"values":[{"id":578,"text":"1 NO (Mag) and 1 NC (Demag)"}]},{"property":{"id":115,"text":"Control / Power Isolation","type":1,"pre":"","pos":""},"values":[{"id":579,"text":"3500 V"}]}],"category":{"id":51,"text":"AC/DC Converters"}},{"id":351,"text":"Mag V","nick":"Converters for Electromagnets (VRT)","emphasis":1,"files":[{"id":20557,"name":"magv site 1","ext":"png","link":"2024/8/20240812113746050","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":17,"text":"Relative Humidity","type":1,"pre":"","pos":""},"values":[{"id":470,"text":"0 to 90% non-condensing"}]},{"property":{"id":18,"text":"Current","type":1,"pre":"","pos":""},"values":[{"id":464,"text":"20A to 50A"}]},{"property":{"id":28,"text":"Supply","type":1,"pre":"","pos":""},"values":[{"id":100,"text":"Complete solution"}]},{"property":{"id":45,"text":"Control Module","type":1,"pre":"","pos":""},"values":[{"id":469,"text":"Encapsulated in epoxy resin with 20,000V/mm insulation."}]},{"property":{"id":54,"text":"Protection Degree","type":1,"pre":"","pos":""},"values":[{"id":472,"text":"IP20"}]},{"property":{"id":65,"text":"Command Voltages","type":1,"pre":"","pos":""},"values":[{"id":465,"text":"100 to 230VAC"},{"id":466,"text":"25 to 110 VAC"}]},{"property":{"id":67,"text":"Lifetime","type":1,"pre":"","pos":""},"values":[{"id":447,"text":"Greater than 20 years or 200 million maneuvers."}]},{"property":{"id":68,"text":"Ambient Temperature","type":1,"pre":"","pos":""},"values":[{"id":468,"text":"0 to 50ºC."}]},{"property":{"id":74,"text":"Call Time","type":1,"pre":"","pos":""},"values":[{"id":467,"text":"0.5 to 5 sec."}]},{"property":{"id":76,"text":"Altitude","type":1,"pre":"","pos":""},"values":[{"id":471,"text":"Up to 1000 meters."}]},{"property":{"id":77,"text":"Maximum Mains Voltage","type":1,"pre":"","pos":""},"values":[{"id":473,"text":"230VAC"}]}],"category":{"id":51,"text":"AC/DC Converters"}},{"id":354,"text":"Evomag","nick":"Complete Systems for Electromagnets with UPS","emphasis":1,"files":[{"id":20547,"name":"Evomag2","ext":"png","link":"2024/8/20240809152518091","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":1,"text":"Voltage","type":1,"pre":"","pos":""},"values":[{"id":109,"text":"Customizable"}]},{"property":{"id":18,"text":"Current","type":1,"pre":"","pos":""},"values":[{"id":101,"text":"Customizable"}]},{"property":{"id":29,"text":"Switching","type":1,"pre":"","pos":""},"values":[{"id":106,"text":"DC with static"},{"id":112,"text":"DC with contactors"}]},{"property":{"id":30,"text":"Demagnetization","type":1,"pre":"","pos":""},"values":[{"id":107,"text":"Automatic with active"},{"id":113,"text":"Automatic with resistors"}]}],"category":{"id":123,"text":"Electromagnet Drive"}},{"id":7,"text":"CM-VRT","nick":"Complete AC/DC Converter System for Electromagnets","emphasis":1,"files":[{"id":20234,"name":"CM-VRT(3)","ext":"png","link":"2024/7/20240730091629790","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":30,"text":"Demagnetization","type":1,"pre":"","pos":""},"values":[{"id":114,"text":"0.4 to 10 seconds"}]},{"property":{"id":63,"text":"Nominal Currents","type":1,"pre":"","pos":""},"values":[{"id":569,"text":"50 to 300 A CC"}]},{"property":{"id":65,"text":"Command Voltages","type":1,"pre":"","pos":""},"values":[{"id":445,"text":"110VAC and 220VAC"}]},{"property":{"id":67,"text":"Lifetime","type":1,"pre":"","pos":""},"values":[{"id":447,"text":"Greater than 20 years or 200 million maneuvers."}]},{"property":{"id":71,"text":"Output Voltage","type":1,"pre":"","pos":""},"values":[{"id":584,"text":"35% higher than the input voltage"}]},{"property":{"id":113,"text":"Fan Voltage","type":1,"pre":"","pos":""},"values":[{"id":583,"text":"110 or 220 VAC"}]},{"property":{"id":116,"text":"Maximum Input Voltage","type":1,"pre":"","pos":""},"values":[{"id":585,"text":"300 VAC"}]}],"category":{"id":123,"text":"Electromagnet Drive"}}]}