{"items":[{"id":430,"text":"ZYGGOT® TOH","nick":"Online Thermography System + Ozone + Humidity","emphasis":1,"files":[{"id":27626,"name":"zyggot-ozonio (2) transparente","ext":"png","link":"2026/2/20260202133644551","lang":"PT","role":"general"}],"properties":[{"property":{"id":7,"text":"Outputs","type":1,"pre":"","pos":""},"values":[{"id":549,"text":"2 Alarm and Trip outputs (N.O.)"},{"id":550,"text":"2 programmable outputs (N.O.)"}]},{"property":{"id":9,"text":"Power Supply","type":1,"pre":"","pos":""},"values":[{"id":9,"text":"24 VDC"}]},{"property":{"id":15,"text":"Inputs","type":1,"pre":"","pos":""},"values":[{"id":40,"text":"4 Analog"},{"id":548,"text":"4 digital (12 to 24 Vdc)"}]},{"property":{"id":16,"text":"Communication","type":1,"pre":"","pos":""},"values":[{"id":35,"text":"Modbus RTU"},{"id":521,"text":"Ethernet"},{"id":522,"text":"Devicenet (Optional)"}]},{"property":{"id":103,"text":"Humidity","type":1,"pre":"","pos":""},"values":[{"id":547,"text":"5 to 95%"}]},{"property":{"id":104,"text":"Screen","type":1,"pre":"","pos":""},"values":[{"id":553,"text":"Color, WVGA Touch Screen"}]}],"category":{"id":132,"text":"Integrated Solution"}},{"id":421,"text":"ZYGGOT® THM+ARC","nick":"Online Thermography System + Ultraviolet Arc Flash Mitigation","emphasis":1,"files":[{"id":27847,"name":"thmarc octo","ext":"png","link":"2026/4/20260423092330294","lang":"PT","role":"general"}],"properties":[{"property":{"id":7,"text":"Outputs","type":1,"pre":"","pos":""},"values":[{"id":482,"text":"2 outputs for Alarm and Trip (N.O.)"},{"id":483,"text":"4 Programmable outputs (N.O.)"}]},{"property":{"id":9,"text":"Power Supply","type":1,"pre":"","pos":""},"values":[{"id":9,"text":"24 VDC"}]},{"property":{"id":15,"text":"Inputs","type":1,"pre":"","pos":""},"values":[{"id":40,"text":"4 Analog"}]},{"property":{"id":16,"text":"Communication","type":1,"pre":"","pos":""},"values":[{"id":35,"text":"Modbus RTU"},{"id":521,"text":"Ethernet"}]},{"property":{"id":17,"text":"Relative Humidity","type":1,"pre":"","pos":""},"values":[{"id":41,"text":"5 to 95 ºC"}]}],"category":{"id":132,"text":"Integrated Solution"}},{"id":1,"text":"ZYGGOT® Temperature","nick":"Online Thermography System","emphasis":2,"files":[{"id":20035,"name":"4-zTemp","ext":"png","link":"2024/7/20240718142533815","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":7,"text":"Outputs","type":1,"pre":"","pos":""},"values":[{"id":1,"text":"V5F (Full): 12 digital outputs"},{"id":2,"text":"V5L (Light / Compact): 4 digital outputs"}]},{"property":{"id":9,"text":"Power Supply","type":1,"pre":"","pos":""},"values":[{"id":9,"text":"24 VDC"}]},{"property":{"id":16,"text":"Communication","type":1,"pre":"","pos":""},"values":[{"id":35,"text":"Modbus RTU"},{"id":481,"text":"Ethernet TCP-IP (included)"}]},{"property":{"id":17,"text":"Relative Humidity","type":1,"pre":"","pos":""},"values":[{"id":41,"text":"5 to 95 ºC"}]},{"property":{"id":37,"text":"Cables","type":1,"pre":"","pos":""},"values":[{"id":132,"text":"From 0.3 to 8 meters"}]}],"category":{"id":2,"text":"Continuous Temperature Monitoring"}},{"id":428,"text":"ZYGGOT® SG TF","nick":"Online Thermography System for Low Voltage Transformers","emphasis":1,"files":[{"id":27010,"name":"sg tf 1","ext":"png","link":"2025/9/20250925101006064","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":16,"text":"Communication","type":1,"pre":"","pos":""},"values":[{"id":555,"text":"Modbus RTU (RS485) and Ethernet (RJ45)"},{"id":581,"text":"API Restful (Web)"},{"id":582,"text":"MQTT (IOT)"}]},{"property":{"id":105,"text":"Resolution","type":1,"pre":"","pos":""},"values":[{"id":554,"text":"0.1ºC"}]},{"property":{"id":106,"text":"Temperatures","type":1,"pre":"","pos":""},"values":[{"id":556,"text":"25 / 5.000 Measurement from -55°C to 150°C"},{"id":557,"text":"Maximum Sensor Temperature: 150°C"},{"id":558,"text":"Gateway Ambient Temperature: -30°C to 105°C"}]},{"property":{"id":107,"text":"Gateway Outputs","type":1,"pre":"","pos":""},"values":[{"id":559,"text":"1 Output: 5A / 250 VAC or 5A / 30 VDC (dry contact)."}]},{"property":{"id":108,"text":"Resolution and Accuracy","type":1,"pre":"","pos":""},"values":[{"id":561,"text":"Accuracy better than 0.2% of the measured value from +10°C to +45°C."},{"id":562,"text":"Accuracy better than 0.3% of the measured value from -40°C to +105°C."},{"id":563,"text":"Accuracy better than 0.4% of the measured value from -55°C to +150°C."}]}],"category":{"id":2,"text":"Continuous Temperature Monitoring"}},{"id":429,"text":"ZYGGOT® SG","nick":"Online Thermography System for Low Voltage","emphasis":1,"files":[{"id":27832,"name":"sg compelto 2026","ext":"png","link":"2026/4/20260417105544470","lang":"PT","role":"general"}],"properties":[{"property":{"id":16,"text":"Communication","type":1,"pre":"","pos":""},"values":[{"id":555,"text":"Modbus RTU (RS485) and Ethernet (RJ45)"},{"id":580,"text":"Modbus TCP"},{"id":581,"text":"API Restful (Web)"},{"id":582,"text":"MQTT (IOT)"}]},{"property":{"id":106,"text":"Temperatures","type":1,"pre":"","pos":""},"values":[{"id":556,"text":"25 / 5.000 Measurement from -55°C to 150°C"},{"id":557,"text":"Maximum Sensor Temperature: 150°C"},{"id":558,"text":"Gateway Ambient Temperature: -30°C to 105°C"}]},{"property":{"id":107,"text":"Gateway Outputs","type":1,"pre":"","pos":""},"values":[{"id":559,"text":"1 Output: 5A / 250 VAC or 5A / 30 VDC (dry contact)."}]},{"property":{"id":108,"text":"Resolution and Accuracy","type":1,"pre":"","pos":""},"values":[{"id":560,"text":"Resolution: 0.01°C"},{"id":561,"text":"Accuracy better than 0.2% of the measured value from +10°C to +45°C."},{"id":562,"text":"Accuracy better than 0.3% of the measured value from -40°C to +105°C."},{"id":563,"text":"Accuracy better than 0.4% of the measured value from -55°C to +150°C."}]}],"category":{"id":2,"text":"Continuous Temperature Monitoring"}},{"id":427,"text":"ZYGGOT® Raddia TS","nick":"Online Thermography System via Radio for Low, Medium and High voltage","emphasis":1,"files":[{"id":27155,"name":"Raddia-Geral","ext":"jpg","link":"2025/10/20251001101257900","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":7,"text":"Outputs","type":1,"pre":"","pos":""},"values":[{"id":484,"text":"1 output for connecting sensors"},{"id":549,"text":"2 Alarm and Trip outputs (N.O.)"},{"id":550,"text":"2 programmable outputs (N.O.)"}]},{"property":{"id":9,"text":"Power Supply","type":1,"pre":"","pos":""},"values":[{"id":9,"text":"24 VDC"}]},{"property":{"id":10,"text":"No. of Sensors","type":1,"pre":"","pos":"Sensores"},"values":[{"id":39,"text":"Up to 125 sensors"}]},{"property":{"id":15,"text":"Inputs","type":1,"pre":"","pos":""},"values":[{"id":40,"text":"4 Analog"},{"id":548,"text":"4 digital (12 to 24 Vdc)"}]},{"property":{"id":16,"text":"Communication","type":1,"pre":"","pos":""},"values":[{"id":586,"text":"ICMP"},{"id":587,"text":"SRTP"},{"id":588,"text":"TCP/IP"},{"id":589,"text":"ETHERNET/IP"},{"id":590,"text":"FTP"},{"id":591,"text":"HTTP"},{"id":592,"text":"ASCII over TCP/IP"},{"id":593,"text":"NTP"}]},{"property":{"id":103,"text":"Humidity","type":1,"pre":"","pos":""},"values":[{"id":547,"text":"5 to 95%"}]},{"property":{"id":104,"text":"Screen","type":1,"pre":"","pos":""},"values":[{"id":553,"text":"Color, WVGA Touch Screen"}]},{"property":{"id":105,"text":"Resolution","type":1,"pre":"","pos":""},"values":[{"id":554,"text":"0.1ºC"}]}],"category":{"id":2,"text":"Continuous Temperature Monitoring"}},{"id":440,"text":"ZYGGOT® Raddia TF","nick":"Online Thermography System via Radio for Transformers","emphasis":1,"files":[{"id":27168,"name":"20250925101006064","ext":"png","link":"2025/10/20251001171101253","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":7,"text":"Outputs","type":1,"pre":"","pos":""},"values":[{"id":549,"text":"2 Alarm and Trip outputs (N.O.)"},{"id":550,"text":"2 programmable outputs (N.O.)"},{"id":551,"text":"1 output for connection to sensors"}]},{"property":{"id":9,"text":"Power Supply","type":1,"pre":"","pos":""},"values":[{"id":9,"text":"24 VDC"}]},{"property":{"id":10,"text":"No. of Sensors","type":1,"pre":"","pos":"Sensores"},"values":[{"id":39,"text":"Up to 125 sensors"}]},{"property":{"id":15,"text":"Inputs","type":1,"pre":"","pos":""},"values":[{"id":40,"text":"4 Analog"},{"id":548,"text":"4 digital (12 to 24 Vdc)"}]},{"property":{"id":16,"text":"Communication","type":1,"pre":"","pos":""},"values":[{"id":35,"text":"Modbus RTU"},{"id":522,"text":"Devicenet (Optional)"},{"id":552,"text":"Ethernet TCP-IP (optional)"}]},{"property":{"id":103,"text":"Humidity","type":1,"pre":"","pos":""},"values":[{"id":547,"text":"5 to 95%"}]},{"property":{"id":104,"text":"Screen","type":1,"pre":"","pos":""},"values":[{"id":553,"text":"Color, WVGA Touch Screen"}]},{"property":{"id":105,"text":"Resolution","type":1,"pre":"","pos":""},"values":[{"id":554,"text":"0.1ºC"}]}],"category":{"id":2,"text":"Continuous Temperature Monitoring"}},{"id":441,"text":"ZYGGOT® ARC V5F","nick":"Ultraviolet Arc Flash Mitigation System - Touch Screen","emphasis":1,"files":[{"id":27003,"name":"arco v5f","ext":"png","link":"2025/9/20250925090428334","lang":"PT","role":"certificate"}],"properties":[{"property":{"id":7,"text":"Outputs","type":1,"pre":"","pos":""},"values":[{"id":484,"text":"1 output for connecting sensors"},{"id":549,"text":"2 Alarm and Trip outputs (N.O.)"},{"id":550,"text":"2 programmable outputs (N.O.)"}]},{"property":{"id":9,"text":"Power Supply","type":1,"pre":"","pos":""},"values":[{"id":9,"text":"24 VDC"}]},{"property":{"id":15,"text":"Inputs","type":1,"pre":"","pos":""},"values":[{"id":40,"text":"4 Analog"},{"id":548,"text":"4 digital (12 to 24 Vdc)"}]},{"property":{"id":16,"text":"Communication","type":1,"pre":"","pos":""},"values":[{"id":35,"text":"Modbus RTU"},{"id":481,"text":"Ethernet TCP-IP (included)"},{"id":522,"text":"Devicenet (Optional)"}]}],"category":{"id":6,"text":"Arc Flash Protection"}},{"id":426,"text":"ZYGGOT® Arc SPL","nick":"Ultraviolet Arc Flash Mitigation for High Selectivity and Low Cost","emphasis":1,"files":[{"id":27736,"name":"spl-main","ext":"jpg","link":"2026/2/20260205165744163","lang":"PT","role":"general"}],"properties":[{"property":{"id":10,"text":"No. of Sensors","type":1,"pre":"","pos":"Sensores"},"values":[{"id":38,"text":"Up to 50 sensors"}]},{"property":{"id":25,"text":"Operating Temperature","type":1,"pre":"","pos":""},"values":[{"id":541,"text":"-20º to 89º C"}]},{"property":{"id":38,"text":"Measuring Angle","type":2,"pre":"","pos":"°"},"values":[{"id":137,"text":"90"}]},{"property":{"id":92,"text":"Power Supply","type":1,"pre":"","pos":""},"values":[{"id":536,"text":"CAN Network"}]},{"property":{"id":93,"text":"UV Wavelength","type":1,"pre":"","pos":""},"values":[{"id":537,"text":"200 to 320 nm"}]},{"property":{"id":94,"text":"Case Type","type":1,"pre":"","pos":""},"values":[{"id":538,"text":"Stainless Steel"}]},{"property":{"id":95,"text":"Radiation Rages","type":1,"pre":"","pos":""},"values":[{"id":539,"text":"UVA and UVB, insensible to visible and IR"}]},{"property":{"id":96,"text":"Sensor Transmission Type","type":1,"pre":"","pos":""},"values":[{"id":540,"text":"High Speed CAN"}]},{"property":{"id":97,"text":"Temperature Storage","type":1,"pre":"","pos":""},"values":[{"id":542,"text":"-40º to 125º C"}]},{"property":{"id":98,"text":"Maximum Measurement Range","type":1,"pre":"","pos":""},"values":[{"id":543,"text":"30m - Depending on Arc Flash Power"}]},{"property":{"id":101,"text":"Indication","type":1,"pre":"","pos":""},"values":[{"id":545,"text":"LED at rear face"}]},{"property":{"id":102,"text":"CE","type":1,"pre":"","pos":""},"values":[{"id":546,"text":"Compliant"}]}],"category":{"id":6,"text":"Arc Flash Protection"}},{"id":3,"text":"ZYGGOT® Arc","nick":"Ultraviolet Arc Flash Mitigation System","emphasis":3,"files":[{"id":27507,"name":"Relé Arco e Sensor-2024 (UV)","ext":"png","link":"2025/11/20251126105719444","lang":"PT","role":"general"}],"properties":[{"property":{"id":7,"text":"Outputs","type":1,"pre":"","pos":""},"values":[{"id":73,"text":"2 redundant trip outputs"}]},{"property":{"id":9,"text":"Power Supply","type":1,"pre":"","pos":""},"values":[{"id":9,"text":"24 VDC"}]},{"property":{"id":10,"text":"No. of Sensors","type":1,"pre":"","pos":"Sensores"},"values":[{"id":38,"text":"Up to 50 sensors"}]},{"property":{"id":17,"text":"Relative Humidity","type":1,"pre":"","pos":""},"values":[{"id":41,"text":"5 to 95 ºC"}]},{"property":{"id":37,"text":"Cables","type":1,"pre":"","pos":""},"values":[{"id":132,"text":"From 0.3 to 8 meters"}]}],"category":{"id":6,"text":"Arc Flash Protection"}},{"id":25,"text":"Portable Arc Tester","nick":"","emphasis":0,"files":[{"id":20613,"name":"gerador arco","ext":"png","link":"2024/8/20240813111553204","lang":"PT","role":"certificate"}],"properties":[],"category":{"id":115,"text":"Support and Add-ons"}},{"id":32,"text":"Fixing support for ZYGGOT sensor","nick":"","emphasis":0,"files":[{"id":20991,"name":"suporte-sensor-2","ext":"png","link":"2024/10/20241024142442383","lang":"PT","role":"certificate"}],"properties":[],"category":{"id":115,"text":"Support and Add-ons"}},{"id":22,"text":"Mains Termination Resistor ZFR","nick":"","emphasis":0,"files":[{"id":20610,"name":"resistor","ext":"png","link":"2024/8/20240813103615639","lang":"PT","role":"certificate"}],"properties":[],"category":{"id":115,"text":"Support and Add-ons"}},{"id":445,"text":"Preview - ZYGGOT® Octogonal (OCTO)","nick":"UV Arc Flash Protection System with high EMI immunity","emphasis":1,"files":[{"id":27557,"name":"octo","ext":"png","link":"2025/12/20251217084641556","lang":"PT","role":"general"}],"properties":[],"category":{"id":6,"text":"Arc Flash Protection"}},{"id":370,"text":"Laser Sight - VLP2","nick":"","emphasis":0,"files":[{"id":20608,"name":"laser site 1","ext":"png","link":"2024/8/20240813103508464","lang":"PT","role":"certificate"}],"properties":[],"category":{"id":115,"text":"Support and Add-ons"}},{"id":31,"text":"Zyggot Temperature VLP5 Installation and Maintenance Case","nick":"with Laser Pointer + ZCC180 Cable","emphasis":0,"files":[{"id":20841,"name":"maleta (1)","ext":"png","link":"2024/9/20240912162636237","lang":"PT","role":"certificate"}],"properties":[],"category":{"id":115,"text":"Support and Add-ons"}},{"id":35,"text":"Zyggot Arc VLP6 Installation and Maintenance Case","nick":"with ZCC180 Cable + ZSA Tester","emphasis":0,"files":[{"id":20836,"name":"maleta (1)","ext":"png","link":"2024/9/20240912161417281","lang":"PT","role":"certificate"}],"properties":[],"category":{"id":115,"text":"Support and Add-ons"}},{"id":28,"text":"Adapter","nick":"For connecting and by passing ZTA cables","emphasis":10,"files":[{"id":20235,"name":"Adaptador (1)","ext":"png","link":"2024/7/20240730092321452","lang":"PT","role":"certificate"}],"properties":[],"category":{"id":115,"text":"Support and Add-ons"}}]}