{"id":429,"text":"ZYGGOT® SG","nick":"Online Thermography System for Low Voltage","description":"The ZYGGOT® SG is an intelligent online thermography system for low-voltage applications, developed for continuous thermal monitoring of connections, busbars and critical points in MCC drawers, Data Centers and shielded busbar systems.\n\nWith ultracompact, self-addressable digital sensors connected through a 1-Wire network, the system simplifies installation, reduces the need for manual configuration and enables real-time tracking of the thermal evolution of electrical assets.\n\nThe readings are concentrated in a gateway, which makes the data available through an embedded web interface, optional local display and native integration with industrial supervision systems via Modbus RTU, Modbus TCP, MQTT, RESTful API, EtherNet/IP, IEC 61850 and PROFINET.\n\nWith a scalable and easy-to-integrate architecture, the ZYGGOT® SG provides continuous visibility over critical temperatures, supporting predictive maintenance strategies, reducing manual inspections and increasing the operational reliability of electrical systems.","files":[{"id":27978,"name":"SG COMPELTO-Tansp","ext":"png","link":"2026/6/20260630115708013","lang":"PT","role":"general"},{"id":27979,"name":"Aplicação2026","ext":"png","link":"2026/6/20260630115720102","lang":"PT","role":"general"},{"id":27980,"name":"gateway-sg-transp","ext":"png","link":"2026/6/20260630115729293","lang":"PT","role":"general"},{"id":27981,"name":"Gateway","ext":"png","link":"2026/6/20260630115735575","lang":"PT","role":"general"},{"id":27982,"name":"Display Frontal","ext":"png","link":"2026/6/20260630115750788","lang":"PT","role":"general"},{"id":27983,"name":"Relay Traseiro","ext":"png","link":"2026/6/20260630115756194","lang":"PT","role":"general"},{"id":27984,"name":"SG-Mono4","ext":"png","link":"2026/6/20260630115819016","lang":"PT","role":"general"},{"id":27985,"name":"SG-Mono2","ext":"png","link":"2026/6/20260630115823144","lang":"PT","role":"general"},{"id":27986,"name":"SG-Duplo 3","ext":"png","link":"2026/6/20260630115827800","lang":"PT","role":"general"},{"id":27987,"name":"SG-Duplo2","ext":"png","link":"2026/6/20260630115833123","lang":"PT","role":"general"},{"id":27988,"name":"SG-duplo1","ext":"png","link":"2026/6/20260630115837700","lang":"PT","role":"general"},{"id":27989,"name":"SG-Duplo-back","ext":"png","link":"2026/6/20260630115844010","lang":"PT","role":"general"},{"id":27990,"name":"DO1","ext":"png","link":"2026/6/20260630115852013","lang":"PT","role":"general"},{"id":27991,"name":"DO4","ext":"png","link":"2026/6/20260630115856226","lang":"PT","role":"general"},{"id":27992,"name":"DO-back","ext":"png","link":"2026/6/20260630115901475","lang":"PT","role":"general"},{"id":28114,"name":"Zyggot_SG_Modbus_Register_Map","ext":"pdf","link":"2026/7/20260728162449748","lang":"PT","role":"general"},{"id":28115,"name":"Zyggot_SG_Modbus_Register_Map","ext":"pdf","link":"2026/7/20260728162654894","lang":"EN","role":"general"},{"id":28118,"name":"Manual de Usuário - ZYGGOT SG (PT-BR) v.21","ext":"pdf","link":"2026/7/20260729152750404","lang":"PT","role":"manual"},{"id":28119,"name":"User Manual - ZYGGOT SG (ENG-US).v21","ext":"pdf","link":"2026/7/20260729153341404","lang":"EN","role":"manual"},{"id":28121,"name":"Catálogo - ZYGGOT SG (PT-BR)","ext":"pdf","link":"2026/7/20260729155530734","lang":"PT","role":"catalog"},{"id":28122,"name":"Catalog - ZYGGOT SG (ENG-US)","ext":"pdf","link":"2026/7/20260729160157506","lang":"EN","role":"catalog"}],"shared":[],"categories":[{"id":2,"text":"Continuous Thermal Monitoring (CTM)","sub":[]}],"properties":[{"property":{"id":8,"text":"Sensors","type":1,"pre":"","pos":""},"values":[{"id":616,"text":"Single-Port, Dual-Port Vertical, and Dual-Port Horizontal versions"}]},{"property":{"id":14,"text":"Accuracy","type":1,"pre":"","pos":""},"values":[{"id":612,"text":"<0.2% from 10 °C to 45 °C and <0.3% from -40 °C to 105 °C"}]},{"property":{"id":16,"text":"Communication","type":1,"pre":"","pos":""},"values":[{"id":555,"text":"Modbus RTU (RS485) and Ethernet (RJ45)"},{"id":580,"text":"Modbus TCP"},{"id":582,"text":"MQTT (IOT)"},{"id":589,"text":"ETHERNET/IP"},{"id":619,"text":"RESTful HTTP API"},{"id":620,"text":"IEC 61850 MMS"},{"id":621,"text":"PROFINET IO-Device"},{"id":622,"text":"Ethernet 10/100 Mbps"}]},{"property":{"id":37,"text":"Cables","type":1,"pre":"","pos":""},"values":[{"id":614,"text":"USB-C cables from 0.25 m to 8 m"}]},{"property":{"id":86,"text":"Interface","type":1,"pre":"","pos":""},"values":[{"id":617,"text":"Local Display and Embedded Web Interface"}]},{"property":{"id":106,"text":"Temperatures","type":1,"pre":"","pos":""},"values":[{"id":557,"text":"Maximum Sensor Temperature: 150°C"},{"id":558,"text":"Gateway Ambient Temperature: -30°C to 105°C"}]},{"property":{"id":107,"text":"Gateway Outputs","type":1,"pre":"","pos":""},"values":[{"id":559,"text":"1 Output: 5A / 250 VAC or 5A / 30 VDC (dry contact)."}]},{"property":{"id":108,"text":"Resolution and Accuracy","type":1,"pre":"","pos":""},"values":[{"id":560,"text":"Resolution: 0.01°C"},{"id":561,"text":"Accuracy better than 0.2% of the measured value from +10°C to +45°C."},{"id":562,"text":"Accuracy better than 0.3% of the measured value from -40°C to +105°C."}]},{"property":{"id":119,"text":"Capacity per Gateway","type":1,"pre":"","pos":""},"values":[{"id":608,"text":"Up to 25, 50, 200, or 400 sensors, depending on the model used."}]},{"property":{"id":120,"text":"Channels per Gateway","type":1,"pre":"","pos":""},"values":[{"id":609,"text":"1, 2, 8, or 16 channels, depending on the variant."}]},{"property":{"id":121,"text":"Sensors per Channel","type":1,"pre":"","pos":""},"values":[{"id":610,"text":"25 sensors"}]},{"property":{"id":122,"text":"Operating Range","type":1,"pre":"","pos":""},"values":[{"id":611,"text":"-20 °C to +150 °C"}]},{"property":{"id":124,"text":"Integration Applications:","type":1,"pre":"","pos":""},"values":[{"id":618,"text":"SCADA, BMS, DCIM, PLCs, and industrial monitoring platforms"}]}],"advantages":[{"text":"Thermographic monitoring for MCC, Data Center, Busbar, etc","icon":{"id":26945,"name":"Ativo 368","ext":"png","link":"2025/9/20250923094712020","lang":"PT","role":"general"}},{"text":"Modbus RTU (RS485) and Ethernet communication","icon":{"id":26946,"name":"Ativo 376","ext":"png","link":"2025/9/20250923095057578","lang":"PT","role":"general"}},{"text":"Compatible with Busbar type shielded busbars","icon":{"id":26947,"name":"Ativo 352","ext":"png","link":"2025/9/20250923095302444","lang":"PT","role":"general"}},{"text":"Up to 400 sensors, depending on the gateway variant.","icon":{"id":26948,"name":"Ativo 370","ext":"png","link":"2025/9/20250923095619884","lang":"PT","role":"general"}},{"text":"One Wire network","icon":{"id":27001,"name":"ativo 359","ext":"png","link":"2025/9/20250924141912404","lang":"PT","role":"general"}},{"text":"Display for real-time monitoring","icon":{"id":27002,"name":"ativo 374","ext":"png","link":"2025/9/20250924141952916","lang":"PT","role":"general"}}],"sections":[{"text":"Thermal failures do not give warning before they happen.","type":22,"nickname":"","desc":"In electrical panels, MCCs, and busbars, abnormal heating can develop silently in connections, terminals, and points with higher current flow.\n\nWhen monitoring relies only on periodic inspections, the failure can evolve between one measurement and the next, increasing the risk of downtime, corrective maintenance, and loss of availability.","video":"","image":{},"cards":[{"text":"Limited visibility of the asset at the time of inspection.","desc":"","link":"","image":{"id":27993,"name":"Ativo 424","ext":"png","link":"2026/6/20260630141321201","lang":"PT","role":"general"},"specs":[]},{"text":"Thermal failures may evolve without being detected.","desc":"","link":"","image":{"id":27995,"name":"Ativo 418","ext":"png","link":"2026/6/20260630141404362","lang":"PT","role":"general"},"specs":[]},{"text":"Increased costs due to downtime and corrective maintenance.","desc":"","link":"","image":{"id":27996,"name":"Ativo 511","ext":"png","link":"2026/6/20260630141442786","lang":"PT","role":"general"},"specs":[]},{"text":"Lack of thermal history to track heating trends.","desc":"","link":"","image":{"id":27997,"name":"Ativo 406","ext":"png","link":"2026/6/20260630141645668","lang":"PT","role":"general"},"specs":[]}],"link_text":""},{"text":"Real-time temperature monitoring, directly at critical points","type":16,"nickname":"","desc":"ZYGGOT® SG transforms temperature monitoring into a continuous process. The sensors are installed at critical points on the electrical equipment and send readings to the gateway, which aggregates the data and makes the information available for visualization, alarms, and integration with industrial systems.\n\nEach sensor has its own unique identifier and is automatically recognized by the system, simplifying installation and reducing the risk of configuration errors.","video":"","image":{},"cards":[{"text":"1. Sensors installed on the asset","desc":"Used in connections, busbars, terminals, and areas prone to overheating.","link":"","image":{"id":28050,"name":"ponto1","ext":"jpg","link":"2026/7/20260709120259566","lang":"PT","role":"general"},"specs":[]},{"text":"2. Continuous temperature reading","desc":"Critical points are now monitored in real time.","link":"","image":{"id":28051,"name":"ponto2","ext":"jpg","link":"2026/7/20260709120404851","lang":"PT","role":"general"},"specs":[]},{"text":"3. Gateway ZYGGOT SG","desc":"It aggregates sensor readings and organizes system data.","link":"","image":{"id":28052,"name":"ponto3","ext":"jpg","link":"2026/7/20260709120512268","lang":"PT","role":"general"},"specs":[]},{"text":"4. Oversight and Decision-Making","desc":"The information can be monitored locally or integrated into the operational systems.","link":"","image":{"id":28053,"name":"ponto4","ext":"jpg","link":"2026/7/20260709120611508","lang":"PT","role":"general"},"specs":[]}],"link_text":""},{"text":"Real-time temperature readings","type":24,"nickname":"","desc":"Temperature readings are available in real time and can be monitored locally or remotely.","video":"","image":{},"cards":[{"text":"Communication protocols","desc":"","link":"","image":{},"specs":[{"key":"MQTT","val":"Data transmission in JSON to IoT platforms, cloud environments, and monitoring systems.","file":{}},{"key":"Integrated Web Server","val":"Local access to readings, alarms, and settings via browser.","file":{}},{"key":"Modbus RTU (RS-485)","val":"Industrial serial communication via RS-485.","file":{}},{"key":"Modbus TCP","val":"Industrial communication via Ethernet network.","file":{}},{"key":"RESTful API (HTTP)","val":"Integration via HTTP with web systems, supervisory systems, and corporate applications.","file":{}},{"key":"EtherNet/IP","val":"Integration with PLCs and industrial automation systems.","file":{}},{"key":"IEC-61850","val":"Integration with electrical automation and substation systems.","file":{}},{"key":"PROFINET IO-Device","val":"Integration with industrial networks and automation systems compatible with PROFINET.","file":{}}]}],"link_text":""},{"text":"","type":22,"nickname":"","desc":"","video":"","image":{},"cards":[{"text":"Digital self-addressable sensors with USB-C connectors for fast installation and simple automatic mapping.","desc":"","link":"","image":{"id":26970,"name":"Ativo 395","ext":"png","link":"2025/9/20250923145100837","lang":"PT","role":"general"},"specs":[]},{"text":"Digital architecture in which the failure of one sensor does not compromise the other monitored points.","desc":"","link":"","image":{"id":26971,"name":"Ativo 414","ext":"png","link":"2025/9/20250923145135578","lang":"PT","role":"general"},"specs":[]},{"text":"Real-time readings with access via web interface, optional local display and industrial protocols.","desc":"","link":"","image":{"id":26972,"name":"Ativo 419","ext":"png","link":"2025/9/20250923145200094","lang":"PT","role":"general"},"specs":[]},{"text":"Low operating cost with sensors powered by the network itself, no batteries and reduced need for manual inspections.","desc":"","link":"","image":{"id":26973,"name":"Ativo 510","ext":"png","link":"2025/9/20250923145229061","lang":"PT","role":"general"},"specs":[]},{"text":"Scalability of up to 25, 50, 200 or 400 sensors per gateway, depending on the system variant.","desc":"","link":"","image":{"id":26974,"name":"Ativo 402","ext":"png","link":"2025/9/20250923145255902","lang":"PT","role":"general"},"specs":[]},{"text":"Stable digital measurement at critical points, with configurable correction and visual identification through a controlled LED.","desc":"","link":"","image":{"id":26975,"name":"Ativo 418","ext":"png","link":"2025/9/20250923145318701","lang":"PT","role":"general"},"specs":[]}],"link_text":""},{"text":"Application in critical low-voltage electrical equipment","type":1,"nickname":"","desc":"ZYGGOT® SG is recommended for installations where the temperature of connections and busbars must be continuously monitored to ensure safety, reliability, and operational continuity.","video":"","image":{},"cards":[{"text":"Data Center","desc":"Support for power availability in mission-critical environments.","link":"","image":{"id":26995,"name":"data center","ext":"png","link":"2025/9/20250924100729573","lang":"PT","role":"general"},"specs":[]},{"text":"MCC Drawers","desc":"Monitoring of internal and external connections in motor control centers.","link":"","image":{"id":26996,"name":"gaveta ccm","ext":"png","link":"2025/9/20250924100753898","lang":"PT","role":"general"},"specs":[]},{"text":"Busbar","desc":"Monitoring of critical connections in shielded busbars and power distribution systems.","link":"","image":{"id":26997,"name":"busbar","ext":"png","link":"2025/9/20250924100812190","lang":"PT","role":"general"},"specs":[]}],"link_text":""},{"text":"Learn about ZYGGOT SG","type":15,"nickname":"","desc":"","video":"https://www.youtube.com/embed/Tu48GxUNIy4","image":{},"cards":[],"link_text":""}]}