{"id":10,"text":"Mykron","nick":"Power Controller","description":"MyKron power controllers from Varixx (SOLIDVAR line) are designed to deliver high performance, reliability, and efficiency in demanding industrial power control applications. Built with robust technology and engineered to operate in challenging environments, they deliver precise power to resistive, inductive, or motor loads – in single-phase, two-phase, or three-phase systems. Ideal for furnaces, ovens, transformers, and heaters, MyKron ensures stability, safety, and protection in every cycle.","files":[{"id":15413,"name":"User Manual Mykron (EN)","ext":"pdf","link":"2023/6/20230621113452911","lang":"EN","role":"manual"},{"id":19362,"name":"Apresentação Controladores de potência - Mykron","ext":"pdf","link":"2023/9/20230918084430277","lang":"PT","role":"certificate"},{"id":20559,"name":"mykron site 1","ext":"png","link":"2024/8/20240812130429041","lang":"PT","role":"certificate"},{"id":20560,"name":"mykron site 2","ext":"png","link":"2024/8/20240812130440992","lang":"PT","role":"certificate"},{"id":20561,"name":"mykron site 3","ext":"png","link":"2024/8/20240812130453837","lang":"PT","role":"certificate"},{"id":26608,"name":"Manual do Usuário Mykron (PTBR)","ext":"pdf","link":"2025/5/20250508111331482","lang":"PT","role":"manual"},{"id":26609,"name":"Catálogo Mykron Controlador de Potência (PTBR)","ext":"pdf","link":"2025/5/20250508111517376","lang":"PT","role":"catalog"},{"id":26610,"name":"Catalog Power Controller Mykron (US)","ext":"pdf","link":"2025/5/20250508111711279","lang":"EN","role":"catalog"},{"id":26644,"name":"Catalogo Mykron - Controlador de Potencia (ESP)","ext":"pdf","link":"2025/5/20250512101714334","lang":"ES","role":"catalog"}],"shared":[],"categories":[{"id":25,"text":"Driving Resistive Loads","sub":[]},{"id":18,"text":"Motor Drive","sub":[]}],"properties":[{"property":{"id":9,"text":"Power Supply","type":1,"pre":"","pos":""},"values":[{"id":80,"text":"110 VAC and 220 VAC"}]},{"property":{"id":18,"text":"Current","type":1,"pre":"","pos":""},"values":[{"id":97,"text":"10A to 2000A"}]},{"property":{"id":44,"text":"Version","type":1,"pre":"","pos":""},"values":[{"id":174,"text":"Single phase"},{"id":175,"text":"Biphasic"},{"id":176,"text":"Three-phase"}]},{"property":{"id":45,"text":"Control Module","type":1,"pre":"","pos":""},"values":[{"id":177,"text":"Unique for all tracks"}]},{"property":{"id":46,"text":"Current Limitation","type":1,"pre":"","pos":""},"values":[{"id":178,"text":"Adjustable"}]},{"property":{"id":61,"text":"Functions / Operating Modes","type":1,"pre":"","pos":""},"values":[{"id":435,"text":"Normal / Constant current"},{"id":436,"text":"Adjustable current limiter"},{"id":437,"text":"Current integrator"}]},{"property":{"id":62,"text":"Nominal Voltage","type":1,"pre":"","pos":""},"values":[{"id":438,"text":"220V"},{"id":439,"text":"380V"},{"id":440,"text":"440V"}]}],"advantages":[{"text":"Precise control of power delivered to the load","icon":{"id":26791,"name":"Ativo 369","ext":"png","link":"2025/7/20250702084557262","lang":"PT","role":"general"}},{"text":"Built-in protections against faults and overloads.","icon":{"id":26792,"name":"Ativo 522","ext":"png","link":"2025/7/20250702085711017","lang":"PT","role":"general"}},{"text":"Supports 0–10V, 4–20mA, and potentiometer signals","icon":{"id":26793,"name":"Ativo 383","ext":"png","link":"2025/7/20250702085742950","lang":"PT","role":"general"}},{"text":"Plug-in control module, easy to replace","icon":{"id":26794,"name":"Ativo 360","ext":"png","link":"2025/7/20250702092608455","lang":"PT","role":"general"}},{"text":"Reduces noise and harmonics on the power grid","icon":{"id":26795,"name":"Ativo 523","ext":"png","link":"2025/7/20250702094401038","lang":"PT","role":"general"}},{"text":"Analog output for real-time current reading","icon":{"id":26796,"name":"Ativo 357","ext":"png","link":"2025/7/20250702094552045","lang":"PT","role":"general"}}],"sections":[{"text":"","type":19,"nickname":"","desc":"Varixx Power Controllers are ideal for ensuring efficiency and precision in energy control in various industrial processes, offering safety and versatility with their protection options in the Plus model.","video":"","image":{"id":20436,"name":"Mykron Banner","ext":"png","link":"2024/8/20240807114023044","lang":"PT","role":"general"},"cards":[],"link_text":""},{"text":"Applications","type":20,"nickname":"Applications","desc":"","video":"","image":{},"cards":[{"text":"Motor","desc":"","link":"","image":{"id":26806,"name":"motor","ext":"jpg","link":"2025/7/20250702141441881","lang":"PT","role":"general"},"specs":[]},{"text":"Industrial oven","desc":"","link":"","image":{"id":26807,"name":"forno","ext":"jpg","link":"2025/7/20250702141506347","lang":"PT","role":"general"},"specs":[]},{"text":"Lighting systems","desc":"","link":"","image":{"id":26808,"name":"light-sistem","ext":"jpg","link":"2025/7/20250702141528888","lang":"PT","role":"general"},"specs":[]},{"text":"Oven","desc":"","link":"","image":{"id":26809,"name":"estufa","ext":"jpg","link":"2025/7/20250702141605372","lang":"PT","role":"general"},"specs":[]},{"text":"Extruder","desc":"","link":"","image":{"id":26810,"name":"extrusora","ext":"jpg","link":"2025/7/20250702141623897","lang":"PT","role":"general"},"specs":[]}],"link_text":""},{"text":"Plus Model","type":24,"nickname":"Plus Model","desc":"The Plus Model is ideal for applications that require greater safety and precision in power control, providing comprehensive protection and advanced closed-loop operation capabilities.","video":"","image":{},"cards":[{"text":"Built-in Protections","desc":"","link":"","image":{},"specs":[{"key":"Lack of Phase at Input and Output","val":"Protects the system against the absence of phase, preventing damage to the equipment.","file":{}},{"key":"Over-Temperature","val":"Monitors the module's temperature, preventing overheating.","file":{}},{"key":"Breaking Load Resistance","val":"Detects when the load resistance is broken, ensuring system safety.","file":{}},{"key":"Current Limiter/Constant Current","val":"Maintains constant current, even with variations in mains voltage.","file":{}},{"key":"Short Circuit","val":"Protects against short circuits that could damage the controller and load.","file":{}}]},{"text":"Signs","desc":"","link":"","image":{},"specs":[{"key":"Control On","val":"Indicates that the controller is in operation.","file":{}},{"key":"Short Circuit","val":"Indicates that a short circuit has occurred.","file":{}},{"key":"Power On","val":"Shows that energy is being supplied to the load.","file":{}},{"key":"Control Signal Failure","val":"Indicates problems with the control signal.","file":{}},{"key":"Current Limiter/Constant Current","val":"Indicates that the current limiter or constant current mode is active.","file":{}},{"key":"Module Over-Temperature","val":"Warning about module overheating.","file":{}},{"key":"Lack of Phase/Resistance Break","val":"Signals absence of phase or break in resistance.","file":{}}]},{"text":"Operating Modes","desc":"","link":"","image":{},"specs":[{"key":"Open mesh","val":"The controller operates without feedback, adjusting power based on the input signal","file":{}},{"key":"Closed mesh","val":"The controller attempts to maintain constant current through the load, automatically adjusting to compensate for variations in voltage and impedance.","file":{}}]},{"text":"Analog Outputs","desc":"","link":"","image":{},"specs":[{"key":"0 - 5V Output","val":"Proportional to current, can be used for ammeter or PLC.","file":{}}]}],"link_text":""},{"text":"Meet Hyamp","type":11,"nickname":"Meet Hyamp","desc":"Our system integrates one or more power controllers, along with all the necessary accessories, in a customizable way, simplifying both installation and operation. \n\nThis system, ready for immediate use, only requires the connection of the power supply and loads. It adapts effectively to resistive and inductive loads of up to 1200 A, whether single-phase, two-phase or three-phase.","video":"https://www.varixx.com.br/detalhes-produto/9/hyamp-sistemas-completos-de-controle-de-potencia","image":{"id":20422,"name":"hyamp","ext":"png","link":"2024/8/20240806144642589","lang":"PT","role":"general"},"cards":[],"link_text":""},{"text":"Control Modes","type":16,"nickname":"Control Modes","desc":"","video":"","image":{},"cards":[{"text":"Pulse Train Type","desc":"The \"Pulse Train\" control system modulates pulse width proportionally to the input signal, switching at zero voltage (turn-on) and zero current (turn-off) to reduce noise and harmonics. It is suitable for controlling resistive loads but not recommended for lighting systems due to the intermittent energy delivery, which can cause undesirable effects.","link":"","image":{"id":26803,"name":"trem de pulso","ext":"png","link":"2025/7/20250702110742260","lang":"PT","role":"general"},"specs":[]},{"text":"Phase Angle Type","desc":"In this mode of operation, the firing angle of the thyristors is adjusted cycle by cycle according to the control signal, with turn-off synchronized at the zero current crossing to minimize transients. The method provides precise and efficient control, being compatible with any type of load.","link":"","image":{"id":26805,"name":"ângulo de fase","ext":"png","link":"2025/7/20250702111059823","lang":"PT","role":"general"},"specs":[]}],"link_text":""}]}