{"id":103,"category":{"id":3,"text":"Destaques e Notícias"},"title":"Arc Quenching Devices (AQD), NBR 17227 and Ultrafast Protection Against Arc Flash","created_at":"2025-6-6","link_url":"https://www.varixx.com/en/products-by-category/protection-and-monitoring_arc-flash-protection","link_text":"Learn more","icon":{"id":26711,"name":"aqd capa eng","ext":"jpg","link":"2025/6/20250606134944132","lang":"EN","role":"general"},"html":"<div><span style=\"white-space-collapse: preserve;\">Understand how the new <strong>ABNT NBR 17227</strong> standard, now aligned with <strong>IEEE 1584:2018</strong> incident energy calculations, redefines arc flash risk &mdash; and how ultrafast Arc Quenching Devices with UV detection elevate industrial safety.</span></div>\r\n<p><span style=\"font-size: 14pt;\"><strong><span style=\"white-space-collapse: preserve;\">Arc Flash Protection: What Does NBR 17227 Say?</span></strong></span></p>\r\n<p><span style=\"white-space-collapse: preserve;\">First and foremost, it is essential to understand why arc flash protection has become one of the most critical safety pillars in industrial electrical engineering. The increasing complexity of electrical systems, combined with high-energy-density environments such as heavy industries, demands faster and more effective mitigation technologies.</span></p>\r\n<p>The recently revised ABNT NBR 17227 standard provides guidelines for managing the risks associated with incident energy, with a focus on technical precautions and calculation methods aimed at arc flash control. This regulatory milestone clearly and technically outlines mitigation actions, offering practical guidance for manufacturers, designers, integrators, and end users.</p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"font-size: 14pt;\"><strong><span style=\"white-space-collapse: preserve;\">What Is Arc Flash and Why Is It So Dangerous?</span></strong></span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"white-space-collapse: preserve;\">An arc flash occurs when the insulating medium (typically air) breaks down, causing an electrical discharge between energized conductors. This discharge releases extreme heat within milliseconds &mdash; enough energy to cause severe burns, melt metal, and trigger explosions.</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"white-space-collapse: preserve;\">The greatest technical challenge is not merely preventing arc flash from occurring but drastically reducing the time between arc initiation and the system&rsquo;s protective response. This is where ultrafast detection technologies come into play.</span>&nbsp;</p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"font-size: 14pt;\"><strong><span style=\"white-space-collapse: preserve;\">Arc Quenching Devices and NBR 17227</span></strong></span>&nbsp;</p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"white-space-collapse: preserve;\">The standard outlines several approaches to arc flash mitigation, including:</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: PT-BR;\">&bull;&nbsp;</span><span style=\"white-space-collapse: preserve;\">Reinforced equipment structures to withstand arc blast pressure;<br /><span style=\"font-family: 'Times New Roman', serif; font-size: 16px; white-space-collapse: collapse;\">&bull;&nbsp;</span>High-performance thermal PPE;<br /><span style=\"font-family: 'Times New Roman', serif; font-size: 16px; white-space-collapse: collapse;\">&bull;&nbsp;</span>More sensitive protection relays;<br /><span style=\"font-family: 'Times New Roman', serif; font-size: 16px; white-space-collapse: collapse;\">&bull;&nbsp;</span>Modern, high-speed circuit breakers;<br /><span style=\"font-family: 'Times New Roman', serif; font-size: 16px; white-space-collapse: collapse;\">&bull;&nbsp;</span>Arc detection and quenching systems.</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"white-space-collapse: preserve;\">Among these, arc detection and quenching systems stand out as the most effective at reducing incident energy because they directly impact response time.<br /><br /><strong>The shorter the response time, the lower the incident energy.</strong> This is the only adjustable parameter that doesn&rsquo;t require modifying the installed load.</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 3;\"><span style=\"font-size: 14pt;\"><strong><span style=\"white-space-collapse: preserve;\">Technical Comparison of Detection Technologies</span></strong></span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 3;\"><strong><span style=\"font-size: 13.5pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: PT-BR;\"><img src=\"https://cp.varixx.com.br/file/2025/6/20250606140315043\" alt=\"\" width=\"1068\" height=\"261\" /></span></strong></p>\r\n<p><span style=\"white-space-collapse: preserve;\">Ultraviolet (UV) detection offers a decisive advantage: it identifies the arc in the <strong>pre-arc phase</strong> &mdash; even before visible light is emitted. This enables immediate operation of circuit breakers and disconnects, with response times significantly faster than traditional systems based on visible light and current measurement.</span></p>\r\n<p><span style=\"white-space-collapse: preserve;\">This difference can determine whether an event remains under control or escalates into a serious accident.<br /></span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"white-space-collapse: preserve;\">At Varixx, all products in the <strong>ZYGGOT Arc</strong> line incorporate UV sensors with ultrafast detection capability.</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"font-size: 14pt;\"><strong><span style=\"white-space-collapse: preserve;\">NBR 17227 Emphasizes Effectiveness and Practicality</span></strong></span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"white-space-collapse: preserve;\">The standard reinforces that the most recommended solutions must combine:</span><span style=\"font-family: 'Times New Roman', serif; font-size: 12pt;\">:</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"font-family: 'Times New Roman', serif; font-size: 16px;\">&bull;&nbsp;</span><span style=\"white-space-collapse: preserve;\">High effectiveness in reducing incident energy;<br /></span><span style=\"font-family: 'Times New Roman', serif; font-size: 16px;\">&bull;&nbsp;</span><span style=\"white-space-collapse: preserve;\">Easy implementation in both new and existing assets;<br /></span><span style=\"font-family: 'Times New Roman', serif; font-size: 16px;\">&bull;&nbsp;</span><span style=\"white-space-collapse: preserve;\">Supply by companies with technical support, documentation, and international presence.</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"white-space-collapse: preserve;\">In this context, devices based on UV sensors with direct circuit breaker operation (ultrafast trip relay output connected to breaker coil) have become the <strong>gold standard</strong> in industrial electrical protection.</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 3;\"><span style=\"white-space-collapse: preserve; font-size: 14pt;\"><strong>ZYGGOT<sup>&reg;</sup>: Pioneering Ultrafast UV Detection Sensors</strong></span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 3;\"><span style=\"white-space-collapse: preserve;\">Varixx is the <strong>world&rsquo;s first and only manufacturer</strong> using dedicated UV sensors for arc flash protection. The ZYGGOT sensor line offers:</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"font-family: 'Times New Roman', serif; font-size: 16px;\">&bull;&nbsp;</span><span style=\"white-space-collapse: preserve;\">UV-only detection &mdash; no need for light transformers or current transformers (CTs);<br /></span><span style=\"font-family: 'Times New Roman', serif; font-size: 16px;\">&bull;&nbsp;</span><span style=\"white-space-collapse: preserve;\">Response time under 0.3 ms &mdash; the fastest in the industry;<br /></span><span style=\"font-family: 'Times New Roman', serif; font-size: 16px;\">&bull;&nbsp;</span><span style=\"white-space-collapse: preserve;\">Robust architecture with easy integration into both new and legacy systems.</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"white-space-collapse: preserve;\">In addition, Varixx provides national and international technical support, full documentation, and strict certifications in industrial safety.</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"font-size: 12.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: PT-BR;\"><img src=\"https://cp.varixx.com.br/file/2025/6/20250606140322351\" alt=\"\" width=\"746\" height=\"758\" /></span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"font-size: 14pt;\"><strong><span style=\"white-space-collapse: preserve;\">Conclusion</span></strong></span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"white-space-collapse: preserve;\">The <strong>NBR 17227</strong> standard marks a crucial advancement in raising industrial electrical safety standards across Brazil and Latin America. More than a regulatory benchmark, it provides clear directives for mitigating incident energy &mdash; one of the greatest risks in today&rsquo;s industrial environments.</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"white-space-collapse: preserve;\">However, the effectiveness of this standard depends directly on the conscious adoption of the right technologies. That&rsquo;s where systems with UV sensors and ultrafast quenching &mdash; like Varixx&rsquo;s ZYGGOT Arc line &mdash; stand out as robust, efficient, and adaptable solutions for both new and existing facilities.</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><span style=\"white-space-collapse: preserve;\">By choosing this technology, your company protects lives, safeguards strategic assets, and ensures operational continuity with an intelligent, fast, and technically superior system &mdash; offering excellent cost-effectiveness.</span></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"><strong><span style=\"white-space-collapse: preserve;\">Discover the ZYGGOT Arc family and learn how your facility can become a benchmark in electrical safety with the most advanced arc flash protection technology available.</span></strong></p>\r\n<p class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\">&nbsp;</p>"}